Structure features: the design of fixed rotor with insert column has higher oil distribution accuracy and mechanical efficiency.
Rolling bearing design, can withstand higher lateral force.
Import shaft seal design, high back pressure, series and parallel use of positive and negative conversion to convenient, stable speed.
A variety of oil port, output shaft, flange and other connection forms.
1, intermittent refers to the maximum inlet pressure, continuous working pressure refers to the working pressure difference 2, the motor should not work at the same time under the highest pressure and maximum speed.
3, the motor in intermittent working conditions, the running time should not exceed 10%.
4. The highest working temperature is 80°
5. The maximum allowable back pressure of the motor is 10MPa, but it is recommended not to exceed it. 5MPa, should be connected to the external inlet pipe.
6. It is recommended to operate under 40% of the maximum working pressure for 1 hour before the motor works at full load.
7, the recommended use of 68# anti-wear hydraulic oil, viscosity 37-73CST, cleanliness ISO18/13.
Hot tags: motor for road header, China, Customized, manufacturers, suppliers, for sale, in stock, factory, price
Structure features: the design of fixed rotor with insert column has higher oil distribution accuracy and mechanical efficiency.
Rolling bearing design, can withstand higher lateral force.
Import shaft seal design, high back pressure, series and parallel use of positive and negative conversion to convenient, stable speed.
A variety of oil port, output shaft, flange and other connection forms.
1, intermittent refers to the maximum inlet pressure, continuous working pressure refers to the working pressure difference 2, the motor should not work at the same time under the highest pressure and maximum speed.
3, the motor in intermittent working conditions, the running time should not exceed 10%.
4. The highest working temperature is 80°
5. The maximum allowable back pressure of the motor is 10MPa, but it is recommended not to exceed it. 5MPa, should be connected to the external inlet pipe.
6. It is recommended to operate under 40% of the maximum working pressure for 1 hour before the motor works at full load.
7, the recommended use of 68# anti-wear hydraulic oil, viscosity 37-73CST, cleanliness ISO18/13.